Fujitec Home


Hydraulic Elevators - Technical Specs and Drawings

General Purpose - Front Opening
General Purpose - Front and Rear Opening
Hospital/Service - Front Opening
Hospital/Service - Front and Rear Opening
Cab & Car Frame Height
Overhead Dimensions
   
  For detailed technical specifications and drawings, click on the capacity that meets your needs. This will take you to a page with AutoCAD drawings saved in Drawing Interchange Format (DXF) and Drawing Web Format (DWF).



The WHIP! viewer allows you to view and print AutoCAD drawings without using AutoCAD. Follow this link to get your free WHIP! viewer.


General Purpose - Front Opening

   


   
Capacity
Door Size & System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width

Depth

Width

Depth

Width

Depth

Clear Width
Clear
Depth
2100 3'-0" 1S 6'-0" 5'-1" 5'-8" 4'-3½" 5'-9½" 4'-4¼" 7'-4" 5'-9"
2500 3'-6" 1S/2CO 7'-0" 5'-1" 6'-8" 4'-3½" 6'-9½" 4'-4¼" 8'-4" 5'-9"
3000 3'-6" 1S/2CO 7'-0" 5'-6" 6'-8" 4'-8½" 6'-9½" 4'-9¼" 8'-4" 6'-2"
3500 3'-6" 1S/2CO 7'-0" 6'-2" 6'-8" 5'-4½" 6'-9½" 5'-5¼" 8'-4" 6'-10"
4000 4'-0" 2CO 8'-0" 6'-2" 7'-8" 5'-4½" 7'-9½" 5'-5¼" 9'-4" 6'-10"


General Purpose - Front and Rear Opening


   


   
Capacity
Door Size & System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width

Depth

Width

Depth

Width

Depth

Clear Width
Clear
Depth
2100 3'-0" 1S 6'-0" 5'-8" 5'-8" 4'-3½" 5'-9½" 4'-3½" 7'-4" 6'-8½"
2500 3'-6" 1S/2CO 7'-0" 5'-8" 6'-8" 4'-3½" 6'-9½" 4'-3½" 8'-4" 6'-8½"
3000 3'-6" 1S/2CO 7'-0" 6'-1" 6'-8" 4'-8½" 6'-9½" 4'-8½" 8'-4" 7'-1½"
3500 3'-6" 1S/2CO 7'-0" 6'-9" 6'-8" 5'-4½" 6'-9½" 5'-4½" 8'-4" 7'-9½"
4000 4'-0" 2CO 8'-0" 6'-9" 7'-8" 5'-4½" 7'-9½" 5'-4½" 9'-4" 7'-9½"


Hospital/Service - Front Opening

   


   
Capacity
Door Size & System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width

Depth

Width

Depth

Width

Depth

Clear Width
Clear
Depth
3500 3'-6" 2S 5'-4" 8'-4" 5'-0" 7'-5" 5'-1½" 7'- 5¾" 6'-8" 9'-2"
4000 4'-0" 2S 6'-0" 8'-5" 5'-8" 7'-6" 5'-9½" 7'- 6¾" 7'-4" 9'-3"
4500 4'-0" 2S 6'-0" 9'-2" 5'-8" 8'-3" 5'-9½" 8'-3¾" 7'-4" 10'-0"


Hospital/Service - Front and Rear Opening

   


   
Capacity
Door Size & System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width

Depth

Width

Depth

Width

Depth

Clear Width
Clear
Depth
3500 3'-6" 2S 5'-4" 9'-0½" 5'-0" 7'-5" 5'-1½" 7'-5" 6'-8" 10'-4"
4000 4'-0" 2S 6'-0" 9'-1½" 5'-8" 7'-6" 5'-9½" 7'-6" 7'-4" 10'-5"
4500 4'-0" 2S 6'-0" 9'-10½" 5'-8" 8'-3" 5'-9½" 8'-3" 7'-4" 11'-2"


 


Cab & Car Frame Height

   

Opening Height

Canopy Height Car Frame Height Suspended Ceiling Height
7'-0" 8'-0" 10'-6" 7'-4"
8'-0" 9'-0" 11'-6" 8'-4"
9'-0" 10'-0" 12'-6" 9'-4"
     


Overhead Dimensions

   

Speed (FPM)

Pit Depth (Min)
Overhead
8'-0" Cab 9'-0" Cab 10'-0" Cab
100 5'-0" 12'-0" 13'-0" 14'-0"
125 5'-0" 12'-0" 13'-0" 14'-0"
150 5'-0" 12'-0" 13'-0" 14'-0"
 


 
Hydraulic Elevator Main Menu
elevators escalators & moving walksmodernization service & maintenance
 
about Fujitec Canada, Inc. locations & contacts find help e-mail us