Gearless Elevators - Technical Specs and Drawings

General Purpose - Front Opening
General Purpose - Front and Rear Opening
Hospital/Service - Front Opening
Hospital/Service - Front and Rear Opening
Cab & Car Frame Height
Overhead Dimensions
   
  For detailed technical specifications and drawings, click on the capacity that meets your needs. This will take you to a page with AutoCAD drawings saved in Drawing Interchange Format (DXF) and Drawing Web Format (DWF).



The WHIP! viewer allows you to view and print AutoCAD drawings without using AutoCAD. Follow this link to get your free WHIP! viewer.



General Purpose - Front Opening - DC Gearless @ 500, 700 or 1000 fpm

   


   
Capacity
Door Size & System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width


Depth


Width


Depth


Width


Depth


Clear Width
Clear
Depth
500 or
700 fpm
1000
fpm
2500 3'-6" 1S/2CO 7'-0" 5'-0½" 6'-8" 4'- 3" 6'-9½" 4'-3¾" 8'-4" 8'-6" 7'-0"
3000 3'-6" 1S/2CO 7'-0" 5'-6" 6'-8" 4'-8½" 6'-9½" 4'-9½" 8'-4" 8'-6" 7'-5½"
3500 3'-6" 1S/2CO 7'-0" 6'-2" 6'-8" 5'-4½" 6'-9½" 5'-5¼" 8'-4" 8'-6" 8'-1½"
4000 4'-0" 2CO 8'-0" 6'-2" 7'-8" 5'-4½" 7'-9½" 5'-5¼" 9'-4" 9'-6" 8'-1½"
Note:
(@ 500 or 700 fpm)
1) Add 1" to the hoistway depth for seismic zones.
2) Add 1" to the hoistway depth for CWT safety.
3) Add 2" to the hoistway depth for both CWT safety and seismic zones.
4) Add another 2" to the hoistway width where travel exceeds 300 ft.
   

Note:
(@ 1000 fpm)

1) Add 1" to the hoistway depth for seismic zones.
2) Add 2" to the hoistway depth for CWT safety.
3) Add 3" to the hoistway depth for both CWT safety and seismic zones.


General Purpose - Front and Rear Opening
- DC Gearless @ 500, 700 or 1000 fpm

   


   
Capacity
Door Size & System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width


Depth


Width


Depth


Width


Depth


Clear Width
Clear
Depth
500 or
700 fpm
1000
fpm
2500 3'-6" 1S/2CO 7'-0" 5'-6" 6'-8" 4'-3" 6'-9½" 4'-3" 9'-10" 10'-0" 6'-6½"
3000 3'-6" 1S/2CO 7'-0" 5'-11½" 6'-8" 4'-8½" 6'-9½" 4'-8½" 9'-10" 10'-0" 7'-0"
3500 3'-6" 1S/2CO 7'-0" 6'-7½" 6'-8" 5'-4½" 6'-9½" 5'-4½" 9'-10" 10'-0" 7'-8"
4000 4'-0" 2CO 8'-0" 6'-7½" 7'-8" 5'-4½" 7'-9½" 5'-4½" 10'-10"

11'-0"

7'-8"
Note:
(@ 500 or 700 fpm)
1) Add 1" to the hoistway depth for seismic zones.
2) Add
1½" to the hoistway depth for CWT safety.
3) Add 2
½" to the hoistway depth for both CWT safety and seismic zones.
4) Add another 2" to the hoistway width where travel exceeds 300 ft.
   

Note:
(@ 1000 fpm)

1) Add 1" to the hoistway depth for seismic zones.
2) Add 2" to the hoistway depth for CWT safety.
3) Add 3" to the hoistway depth for both CWT safety and seismic zones.


Hospital/Service - Front Opening
- DC Gearless @ 500 or 700 fpm

   


   
Capacity
Door Size& System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width

Depth

Width

Depth

Width

Depth

Clear Width
Clear
Depth
4000 4'-0" 2S 6'-0" 8'-3" 5'-8" 7'-4" 5'-9½" 7'- 4¾" 8'-3" 9'-3"
4500 4'-0" 2S 6'-0" 8'-9" 5'-8" 7'-10" 5'-9½" 7'-10¾" 8'-3" 9'-9"
5000 4'-0" 2S 6'-0" 9'-5" 5'-8" 8'-6" 5'-9½" 8'- 6¾" 8'-3" 10'-5"
 
Note: 1) Add 1" to the hoistway depth for seismic zones.
2) Add 1" to the hoistway depth for CWT safety.
3) Add 2" to the hoistway depth for both CWT safety and seismic zones.
4) Add another 2" to the hoistway width where travel exceeds 300 ft.


Hospital/Service - Front and Rear Opening
- DC Gearless @ 500 or 700 fpm

   


   
Capacity
Door Size & System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width

Depth

Width

Depth

Width

Depth

Clear Width
Clear
Depth
4000 4'-0" 2S 6'-0" 8'-10" 5'-8" 7'-4" 5'-9½" 7'-4" 8'-5½" 10'-1½"
4500 4'-0" 2S 6'-0" 9'-4" 5'-8" 7'-10" 5'-9½" 7'-10" 8'-5½" 10'-7½"
5000 4'-0" 2S 6'-0" 10'-0" 5'-8" 8'-6" 5'-9½" 8'-6" 8'-5½" 11'-3½"
 
Note: 1) Add 1" to the hoistway depth for seismic zones.
2) Add 2" to the hoistway depth for CWT safety.
3) Add 3" to the hoistway depth for both CWT safety and seismic zones.
4) Add another 2" to the hoistway width where travel exceeds 300 ft.

 


Cab & Car Frame Height
- DC Gearless @ 500, 700 or 1000 fpm

   

Opening Height

Canopy Height Car Frame Height Suspended Ceiling Height
500 or
700 fpm
1000
fpm
7'-0" 8'-0" 11'-0" 10'-6" 7'-4"
8'-0" 9'-0" 12'-0" 11'-6" 8'-4"
9'-0" 10'-0" 13'-0" 12'-6" 9'-4"
 
Note:

1) Add 6" to Car Frame Height for all front and rear opening applications



Overhead Dimensions
- DC Gearless @ 500, 700 or 1000 fpm

   

Speed (FPM)

Pit Depth (Min)
Overhead
8'-0" Cab 9'-0" Cab 10'-0" Cab
500 8'-6" 15'-9" 16'-9" 17'-9"
700 10'-0" 17'-10½" 18'-10½" 19'-10½"
1000 12'-0" 17'-3" 18'-3" 19'-3"
 
Note:

1) Overhead dimension is from top landing floor to underneath of machine beam which is normally 1'-0" high.
2) Add 6" to Overhead Dimension for all front and rear opening applications.
3) Pit and Overhead shown for 1000fpm are based on ETS application.


 