Fujitec Home




Geared Elevators - Technical Specs and Drawings

General Purpose - Front Opening
General Purpose - Front and Rear Opening
Hospital/Service - Front Opening
Hospital/Service - Front and Rear Opening
Cab & Car Frame Height
Overhead Dimensions
   
 

For detailed technical specifications and drawings, click on the capacity that meets your needs. This will take you to a page with AutoCAD drawings saved in Drawing Interchange Format (DXF) and Drawing Web Format (DWF).



The WHIP! viewer allows you to view and print AutoCAD drawings without using AutoCAD. Follow this link to get your free WHIP! viewer.



General Purpose - Front Opening

   


   
Capacity
Door Size & System

Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width

Depth

Width


Depth


Width

Depth


Clear Width
Clear
Depth
2500 3'-6" 1S/2CO 7'-0" 5'-0½" 6'-8" 4'- 3" 6'-9½" 4'-3¾" 8'-4" 6'-8"
3000 3'-6" 1S/2CO 7'-0" 5'-6" 6'-8" 4'-8½" 6'-9½" 4'-9½" 8'-4" 7'-2"
3500 3'-6" 1S/2CO 7'-0" 6'-2" 6'-8" 5'-4½" 6'-9½" 5'-5¼" 8'-4" 7'-10"
4000 4'-0" 2CO 8'-0" 6'-2" 7'-8" 5'-4½" 7'-9½" 5'-5¼" 9'-4" 7'-10"
Note: 1) Add 1½" to the hoistway depth for seismic zones.
2) Add 5" to the hoistway depth for CWT safety.
3) Add 6½" to the hoistway depth for both CWT safety and seismic zones.


General Purpose - Front and Rear Opening

   


   
Capacity
Door Size & System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width

Depth

Width

Depth

Width

Depth

Clear Width
Clear
Depth
2500 3'-6" 1S/2CO 7'-0" 5'-6" 6'-8" 4'-3" 6'-9½" 4'-3" 9'-6" 6'-6½"
3000 3'-6" 1S/2CO 7'-0" 5'-11½" 6'-8" 4'-8½" 6'-9½" 4'-8½" 9'-6" 7'-0"
3500 3'-6" 1S/2CO 7'-0" 6'-7½" 6'-8" 5'-4½" 6'-9½" 5'-4½" 9'-6" 7'-8"
4000 4'-0" 2CO 8'-0" 6'-7½" 7'-8" 5'-4½" 7'-9½" 5'-4½" 10'-6" 7'-8"
 
Note: 1) Add 1½" to the hoistway depth for seismic zones.
2) Add 5½" to the hoistway depth for CWT safety.
3) Add 5½" to the hoistway depth for both CWT safety and seismic zones.


Hospital/Service - Front Opening

   


   
Capacity
Door Size & System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width

Depth

Width

Depth

Width

Depth

Clear Width
Clear
Depth
4000 4'-0" 2S 6'-0" 8'-3" 5'-8" 7'-4" 5'-9½" 7'- 4¾" 8'-2" 9'-3"
4500 4'-0" 2S 6'-0" 8'-9" 5'-8" 7'-10" 5'-9½" 7'-10¾" 8'-2" 9'-9"
5000 4'-0" 2S 6'-0" 9'-5" 5'-8" 8'-6" 5'-9½" 8'- 6¾" 8'-2" 10'-5"
 
Note: 1) Add 3" to the hoistway depth for seismic zones.
2) Add 4" to the hoistway depth for CWT safety.
3) Add 6½" to the hoistway depth for both CWT safety and seismic zones.


Hospital/Service - Front and Rear Opening

   


   
Capacity
Door Size & System
Platform Size
Clear Inside Applied Panels
Clear Inside Steel Shell
Hoistway
Width

Depth

Width

Depth

Width

Depth

Clear Width
Clear
Depth
4000 4'-0" 2S 6'-0" 8'-10" 5'-8" 7'-4" 5'-9½" 7'-4" 8'-2" 10'-1½"
4500 4'-0" 2S 6'-0" 9'-4" 5'-8" 7'-10" 5'-9½" 7'-10" 8'-2" 10'-7½"
5000 4'-0" 2S 6'-0" 10'-0" 5'-8" 8'-6" 5'-9½" 8'-6" 8'-2" 11'-3½"
 
Note: 1) Add 3" to the hoistway depth for seismic zones.
2) Add 5" to the hoistway depth for CWT safety.
3) Add 9½" to the hoistway depth for both CWT safety and seismic zones.

 

 


Cab & Car Frame Height

   

Opening Height

Canopy Height Car Frame Height Suspended Ceiling Height
7'-0" 8'-0" 10'-6" 7'-4"
8'-0" 9'-0" 11'-6" 8'-4"
9'-0" 10'-0" 12'-6" 9'-4"


Overhead Dimensions

   

Speed (FPM)

Pit Depth (Min)
Overhead
8'-0" Cab 9'-0" Cab 10'-0" Cab
350 5'-6" 14'-2" 15'-2" 16'-2"
500 6'-8" 15'-3" 16'-3" 17'-3"
 
Note:

1) Overhead dimension is from top landing floor to underneath of machine beam which is normally 1'-0" high.
2) Minimum overhead requirements for the city of Chicago, 4" for 350 FPM is to be added.
3) Pit Depth for 350 FPM Hospital/Service is to be 5'-8".

 


 
Geared Elevator Main Menu